PTP Post base 10950.7053
Long text
Connection to wood construction with a post base
Connection to wood construction with PITZL post base 10950.7053 according to ETA-10/0413. The connection to the column of the upper plate (Ø 100 x 6 mm) is made by means of 4 full-thread screws with a diameter of 10 mm and a length of 120 mm. The connection to concrete is done by setting in concrete. A minimum anchoring depth of 150 mm must be observed. The concrete foundation must be verified separately.
The installation height is 450 mm. The required minimum timber dimension is 120/120 mm.
The characteristic load bearing capacity according to timber strength class C24 are:
F1,Rk (Compression) = 100 kN Pressure load capacity in direction of wood support
F1,Rk (Tension) = 30 kN Tension load capacity in direction of wood support
F2/3,Rk = 4,4 kN Horizontal load capacity in direction of longer side of base
F4/5,Rk = 4,4 kN Horizontal load capacity in direction of shorter side of base
By using screws Ø 10 x 160 the char. lift value can be increased to 50 kN.
The number and arrangement of the bases as well as the installation and assembly must be taken from the specifications in accordance with ETA-10/0413. Basically, the requirements of DIN EN 1995 must be fulfilled.
Short text
Connection to wood construction with PITZL post base 10950.7053
Connection to wood construction with PITZL post beam 10950.7053 according to ETA-10/0413. Connection to wood construction with 4 screws diameter 10 mm. The connection to concrete is done by setting in concrete. A minimum anchoring depth of 150 mm must be observed.
Wood construction: 120/120 mm, C24